A study of fetal lung maturity with lower limb epiphyseal centre by USG at primary health care centre
Prashant Nirale
Associate Professor, Department of Radiology, M. I. M. S. R Medical College, Latur, Maharashtra, INDIA. Email: dr_prashantnirale@yahoo.com
Abstract Background: Knowledge of the fetal lung maturity is helpful to make the decision of continuation or termination of pregnancy. It is the key factor for the survival of prematurely delivered newborn baby. Aim: To study fetal lung maturity with the help of USG by measuring lower limb epiphyseal centres at primary health care centre. Material and Methods: Seventy-two patients who were in pre-labor may be at term or preterm were subjected for this randomized study. Patients were scanned in the Department of Radiology for fetal lung maturity. The findings were correlated with other investigative modality, like free floating particles and biparietal diameter (BPD). Results: Nearly all patients with free floating particles have distal femoral epiphysis≥5 mm and proximal tibial epiphysis≥5 mm and almost all patients with biparietal diameter ≥9.0 cm showed mature lower limb epiphyseal centres. Conclusion: Assessment by USG to determinethe fetal lung maturity was useful. Priority should be given to BPD ≥9.0 cm (100%), DFE ≥5 mm (98%) and PTE ≥5 mm (97.7%). Key Words: Fetal lung maturity, ultrasonography, biparietal diameter, distal femoral epiphysis, proximal tibial epiphysis.
Survival of the prematurely delivered newborn infant principally depends on pulmonary function. Lung maturation depends on coordinated development of separate anatomic, biophysical and biochemical factors. Knowledge of the fetal lung maturity is helpful to make the decision of continuation or termination of pregnancy.1 Clinical methods have drawbacks. In many cases patients do not know the exact LMP or date of quickening. Per abdominal examinations can also give erroneous results in cases such as polyhydrominos or multiple gestation or IUGR. Amniocentesis is an invasive technique.2 The epiphyseal ossification centers of the distal femur (DFE) and proximal tibia (PTE) appear and enlarge during the third trimester of pregnancy. Radiological appearance of distal femoral epiphysis and proximal tibial epiphysis are helpful in determination of fetal lung maturity.3 But, use of X-rays is hazardous to fetus. Nowadays, ultrasonography (USG) is available for detection ofdistal femoral and tibial epiphyseal centre, so, it is wise to avoid radiography to know the fetal lung maturity.4This study was conducted with an aim to study fetal lung maturity with the help of USG by measuring lower limb epiphyseal centres at primary health care centre.
MATERIAL AND METHODS Seventy-two patients who were in pre-labor may be at term or preterm were subjected for this randomized study. Patients were scanned in the Department of Radiology for fetal lung maturity. The findings were correlated with other investigative modality, like free floating particles and biparietal diameter (BPD). Technique: The ultrasound scanning was performed with ALOKA SSD-630 real time B mode ultrasound unit with 3.5 MHz convex transducer. Aquasonic jelly was applied all over the abdomen to make good contact between transducer and the skin. The obstetric ultrasound was performed to know the following points:
RESULTS In this study on 72 patients, 50 patients showed distal femoral epiphysis ≥5 mm. Out of these 50 patients, only one showed negative shake test i.e., 98% of these patients with distal femoral epiphysis ≥5 mm and suggest fetal lung maturity. While 45 patients showed proximal tibial epiphysis ≥5 mm. Out of these 45 patients, show positive shake test i.e., 97.77%. Table 1: Correlation between free floating particles and epiphyseal centres of lower limb
Nearly all patients with free floating particles have distal femoral epiphysis≥5 mm and proximal tibial epiphysis≥5 mm.
Table 2: Correlation between biparietal diameter and epiphyseal centres of lower limb
Nearly all patients with biparietal diameter ≥9.0 cm showed mature lower limb epiphyseal centres. DISCUSSION REFERENCES
|
|
|||||||||||||||||||||||||||||||||||||||||||||